Wastewater Treatment Plants Retain Over Ninety-Nine Percent of

Full-scale wastewater treatment facilities achieve exceptionally high microplastic retention primarily through upstream physico-chemical processes rather than downstream biofiltration units, according to an investigation of two operational municipal plants. Re

Illustrative imageIllustrative image

Full-scale wastewater treatment facilities achieve exceptionally high microplastic retention primarily through upstream physico-chemical processes rather than downstream biofiltration units, according to an investigation of two operational municipal plants. Researchers examined particle removal across contrasting operational setups to assess how different biofilter carrier media and fluctuating hydraulic conditions influence overall retention performance and environmental discharge rates.

The study focused on two distinct facilities designated as the Amphora and Almanarre wastewater treatment plants. Both treatment works incorporate primary physical and chemical treatment trains comprising coarse and fine screening, grit and grease removal, and coagulation–flocculation coupled with lamellar settling prior to secondary biofiltration. However, the facilities diverge in their biological filtration configurations: Amphora utilizes natural expanded clay as a biofilter carrier medium, whereas Almanarre relies on floating synthetic polystyrene beads as a growth substrate.

To evaluate performance across varying operational strains, researchers conducted sampling campaigns during both regular periods and high-flow touristic seasons. Microplastics down to a size threshold of 10 micrometers were identified and quantified using focal plane array micro-Fourier transform infrared imaging. This optical analytical technique enabled the research team to evaluate total particle count retention as well as polymer-specific mass dynamics across both treatment facilities.

Analytical observations demonstrated that both facilities maintained remarkably high overall microplastic retention rates, with the vast majority of synthetic debris removed before wastewater reached the biofilter stages. These measurements confirm that conventional physical and chemical separation stages, notably lamellar settling following coagulation and flocculation, serve as the primary defensive barrier against microplastic release in municipal wastewater management.

Despite overall high retention, slight variations emerged between the two operating designs and loading conditions. The Amphora facility consistently maintained removal efficiencies exceeding 99.9 percent by particle counts across both regular and touristic monitoring campaigns. In comparison, the Almanarre plant achieved slightly lower retention efficiencies of 99.65 percent during standard operation and 99.44 percent during high hydraulic loading periods associated with the touristic season.

Mass-balance calculations further illuminated the operational differences between the synthetic and natural carrier configurations under stress. Effluent discharge from Amphora accounted for approximately 0.86 to 1.02 grams of microplastics per day across both observation campaigns. Conversely, daily microplastic release from Almanarre escalated substantially from roughly 2.96 grams per day under baseline conditions to 10.39 grams per day during elevated hydraulic flows, suggesting that polystyrene carrier beads under operational stress may contribute to increased microplastic emissions.

Beyond aquatic effluent discharges, the researchers performed preliminary mass estimations regarding the fate of captured synthetic particles diverted into solid waste streams. The resulting back-of-the-envelope assessment indicated that microplastics accumulated in sewage sludge may present a substantially larger long-term environmental contamination pathway than direct treated liquid discharge.

Based on an estimated annual input of 125.6 kilograms of microplastics applied to agricultural soils through sludge amendment, approximately 15.7 kilograms per year could ultimately migrate away from treated agricultural fields. By contrast, direct aquatic release from treated wastewater effluent accounted for an estimated 2.77 kilograms per year, demonstrating that land-applied sludge can represent a dominant environmental release vector.

Subject of Research: Microplastic retention and emission pathways in full-scale wastewater treatment plants using biofilters

Article Title: Microplastic retention in two wastewater treatment plants using synthetic (polystyrene) and natural (expanded clay) biofilter media

Article References: Iordachescu, L., Papacharalampos, K., Barritaud, L., Denieul, M.-P., Plessis, E., Baratto, G., Julien, V., Syberg, K., & Vollertsen, J. (2026). Microplastic retention in two wastewater treatment plants using synthetic (polystyrene) and natural (expanded clay) biofilter media. Microplastics and Nanoplastics. https://doi.org/10.1186/s43591-026-00255-9

Image Credits: AI Generated

DOI: 10.1186/s43591-026-00255-9

Keywords: Microplastics, Wastewater treatment plants, Biofiltration, Expanded clay, Polystyrene beads, Carrier media, Physico-chemical treatment, Coagulation-flocculation, Lamellar settling, µFTIR imaging, Amphora WWTP, Almanarre WWTP, Mass-balance analysis, Sewage sludge, Agricultural soil, Effluent discharge, Hydraulic loading