Myopia Control Spectacle Lenses Do Not Accelerate Childhood Astigmatism
A retrospective cohort investigation evaluating children fitted with specialized myopia control spectacle lenses has demonstrated that the lenses do not induce significant increases in astigmatism compared with conventional single-vision eyewear over one year
Illustrative imageA retrospective cohort investigation evaluating children fitted with specialized myopia control spectacle lenses has demonstrated that the lenses do not induce significant increases in astigmatism compared with conventional single-vision eyewear over one year of wear. Conducted at The Affiliated Eye Hospital of Suzhou Vocational Health College in Suzhou, China, the research analyzed cycloplegic refraction and optical biometry data from 661 right eyes of young patients aged 6 to 17 years. By converting conventional sphero-cylindrical refractive measurements into orthogonal power vectors, the investigators performed a rigorous quantitative examination of both directional and scalar astigmatic shifts across four distinct lens modalities. The primary finding reveals that while all patient groups exhibited a mild, uniform drift toward with-the-rule astigmatism alongside a modest increase in overall cylinder magnitude over twelve months, these changes did not statistically differ between lens designs after adjusting for baseline characteristics. This outcome offers clinical reassurance regarding ongoing concerns that peripheral defocus or contrast-modulating optical interventions might inadvertently aggravate astigmatism during critical developmental windows.
Spectacle lenses engineered to decelerate pediatric myopia progression have transitioned rapidly from clinical research environments into widespread daily practice. Modern optical strategies predominantly employ three distinct mechanisms to curb excessive eye growth: Defocus Incorporated Multiple Segments, known as DIMS, which impose simultaneous peripheral myopic defocus through an integrated array of miniature lenslets; Highly Aspherical Lenslets, designated as HAL, which project a continuous volume of myopic defocus using concentric rings of aspherical elements; and Diffusion Optics Technology, or DOT, which modulates retinal contrast through thousands of microscopic scattering light elements without altering focal planes. As clinical uptake of these designs has expanded, clinicians have debated whether prolonged exposure to peripheral optical manipulations alters astigmatism in pediatric eyes. Earlier retrospective publications had suggested that certain advanced designs, particularly highly aspherical lenslet configurations, might impose an astigmatic cost by precipitating unwanted cylinder accumulation relative to single-vision lenses. However, prior investigations predominantly evaluated scalar cylinder power alone, obscuring critical rotational and directional nuances that require orthogonal power vector mathematics to resolve properly.
To evaluate these competing hypotheses in routine clinical practice, the investigators reviewed records from 20,879 lens-dispensing visits logged between December 2023 and March 2025 at the specialized eye hospital. From this broader clinical population, 661 children meeting strict inclusion criteria were incorporated into the final analytical cohort. The participants had been fitted according to practitioner recommendations and parental preferences with one of four spectacle interventions: 123 children received traditional single-vision spectacles serving as the reference control; 163 were prescribed DIMS lenses using MiYOSMART technology; 294 were fitted with HAL lenses utilizing Stellest technology; and 81 were provided DOT spectacles featuring Kong You Dian lenses. The cohort exhibited a mean age of 12.57 years, with boys comprising 47.2 percent of the study sample. Follow-up intervals were remarkably consistent across the four groups, averaging 360 days with a standard deviation of 43 days, thereby providing an equitable twelve-month window for evaluating both structural axial growth and refractive transformations under real-world conditions.
Refractive status was ascertained under thorough pharmacological cycloplegia administered by experienced clinical optometrists following an exacting standardized protocol. Cycloplegia was achieved by instilling a combination solution of 0.5 percent tropicamide and 0.5 percent phenylephrine hydrochloride four consecutive times at five-minute intervals, with subjective refractions conducted precisely forty minutes following the final drop once the absence of the pupillary light reflex was confirmed. Optometrists refined cylinder power and axis utilizing Jackson cross-cylinder testing in discrete increments of 0.25 diopters and 1 degree. Concurrently, axial length was quantified with high-precision optical biometry using an IOLMaster 500 instrument at baseline and the one-year follow-up visit. To prevent the loss of directional information that occurs when analyzing scalar cylinder values, the researchers converted each minus-cylinder subjective refraction into Thibos power vector components: J0, representing horizontal and vertical astigmatic power where positive values denote with-the-rule orientation; and J45, capturing oblique astigmatic power at 45 and 135 degrees, alongside the absolute cylinder magnitude.
Across the full sample of 661 pediatric eyes, unadjusted paired analyses identified significant within-group changes from baseline to twelve months across all lens types. Specifically, every cohort showed a significant positive shift in J0, reflecting a consistent drift toward with-the-rule astigmatism that reached statistical significance with probability values below 0.001 in all groups. Unadjusted J0 increases averaged positive 0.210 diopters in the single-vision group, positive 0.232 diopters in the DIMS cohort, positive 0.230 diopters in the HAL group, and positive 0.194 diopters among DOT wearers. Concurrently, total astigmatism increased across all cohorts, exhibiting mean unadjusted increases of positive 0.476 diopters for single vision, positive 0.514 diopters for DIMS, positive 0.510 diopters for HAL, and positive 0.448 diopters for DOT. The J45 vector component showed modest negative shifts in single-vision, DIMS, and HAL wearers, while the DOT group exhibited a small positive change of positive 0.020 diopters, establishing an overall cohort-wide mean shift of negative 0.027 diopters.
Because participants were allocated based on clinical consultation rather than random assignment, baseline demographic and refractive characteristics varied across cohorts, necessitating comprehensive statistical adjustment. The study groups demonstrated statistically significant baseline differences in age, spherical equivalent refraction, total astigmatism, and baseline J0 components. To control for these imbalances, the researchers implemented generalized linear models adjusted for patient age, sex, baseline spherical equivalent refraction, baseline axial length, and the corresponding baseline astigmatism component, applying robust standard errors and Bonferroni corrections for multiple comparisons. In these adjusted models, between-group differences for the primary outcomes vanished entirely: the adjusted Wald test yielded a non-significant probability value of 0.446 for changes in J0 and a value of 0.201 for changes in total astigmatism magnitude. Adjusted mean J0 changes stood at positive 0.264 diopters for single vision, positive 0.227 diopters for DIMS, positive 0.208 diopters for HAL, and positive 0.199 diopters for DOT, demonstrating an absence of lens-induced acceleration.
Although the omnibus test for the secondary vector component J45 revealed a nominally significant between-group divergence with an adjusted probability value of 0.007, detailed pairwise contrasts confirmed that this effect was driven by a single comparison between HAL and DOT wearers. The adjusted difference between HAL and DOT for J45 was negative 0.061 diopters with a 95 percent confidence interval spanning negative 0.097 to negative 0.024 diopters, remaining significant after Bonferroni correction at a probability value of 0.005. Nevertheless, the authors emphasized that a vector discrepancy of 0.061 diopters represents a clinically imperceptible variation, translating to an axis shift of merely one to two degrees at typical pediatric cylinder magnitudes, well beneath the threshold of clinical detection or lens manufacturing steps. None of the other seventeen adjusted pairwise comparisons across vector components and total astigmatic change survived correction for multiplicity, underscoring that specialized optical treatments behave similarly to conventional lenses in their overall astigmatic footprint.
Secondary analyses examining clinically meaningful increases in total astigmatism, defined as an accumulation of 0.50 diopters or more over the observation year, further confirmed the equivalence of lens behaviors. Unadjusted rates of meaningful cylinder increase appeared elevated in certain cohorts, reaching 39.0 percent in single-vision, 46.6 percent in DIMS, 52.7 percent in HAL, and 39.5 percent in DOT wearers. However, following multivariable logistic regression adjusting for baseline confounders, none of the myopia control groups displayed odds that differed significantly from the single-vision reference group. Furthermore, in a sensitivity analysis that excluded seventeen eyes exhibiting extreme astigmatic shifts exceeding 2.0 diopters—all of which entered the study with zero recorded cylinder at baseline—adjusted models reaffirmed the primary findings, demonstrating no significant between-group differences for J0 or total cylinder magnitude, with probability values of 0.081 and 0.134, respectively, confirming that rare outliers did not distort the overarching conclusions.
A critical dimension of the investigation centered on the physiological coupling between ocular elongation and astigmatic change. Mean axial elongation across all 661 participants over twelve months was 0.192 millimeters, with 77 eyes displaying measurable axial shortening. Myopia control lenses performed as anticipated regarding axial slowing, with mean axial elongation measuring 0.269 millimeters in single vision, 0.187 millimeters in DIMS, 0.183 millimeters in HAL, and 0.115 millimeters in DOT wearers. Multivariable linear regression demonstrated that greater axial growth was modestly associated with larger positive shifts in J0, more negative shifts in J45, and larger overall cylinder increases, independent of lens modality. Specifically, each additional millimeter of axial elongation was linked to a positive 0.240 diopter shift in J0 and a positive 0.526 diopter increase in total cylinder. Crucially, interaction terms testing whether this biological coupling varied across lens designs were non-significant, refuting the notion of an optical penalty and suggesting that astigmatic drift arises from normal physiological growth rather than specific therapeutic lens designs.
Subgroup analyses conducted on 413 eyes possessing pre-existing astigmatism at baseline provided further clinical insights, showing substantially smaller increases in total astigmatism averaging only positive 0.179 diopters, compared to positive 0.497 diopters in the full cohort. Within this astigmatic cohort, axis orientation demonstrated remarkable stability: 92.7 percent changed by 10 degrees or less over the year, with a median absolute change of 5.0 degrees, rising to 98.1 percent stability in eyes with at least 0.75 diopters of baseline astigmatism. In this subgroup, the statistical association between axial elongation and cylinder change was attenuated and no longer statistically significant, indicating that documentation conventions in eyes initially coded with zero cylinder partially amplified full-cohort estimates. While noting study limitations including retrospective single-center design, reliance on subjective refraction without corneal topography, and restriction to right eyes, the researchers concluded that concerns regarding astigmatism induction should not deter practitioners from prescribing modern myopia control spectacles to children.
Subject of Research: One-year astigmatic power vector changes and axial elongation in children wearing myopia control spectacle lenses
Article Title: One-year changes in astigmatism after wearing three types of myopia control spectacle lenses: a power vector analysis
Article References: Xing, X., Song, Z., Yu, Q., & Zhang, K. (2026). One-year changes in astigmatism after wearing three types of myopia control spectacle lenses: a power vector analysis. Frontiers in Ophthalmology, 6, 2023351. https://doi.org/10.3389/fopht.2026.2023351
Image Credits: AI Generated
DOI: 10.3389/fopht.2026.2023351
Keywords: astigmatism, myopia control, power vector analysis, defocus incorporated multiple segments, highly aspherical lenslets, diffusion optics technology, single vision lenses, axial elongation, cycloplegic refraction, pediatric ophthalmology, with the rule astigmatism, refractive error, biometry, vector decomposition, ocular growth, spectacle lenses
News Source: Ophelia Keating. (November 26, 2026). Myopia Control Spectacle Lenses Do Not Accelerate Childhood Astigmatism Over One Year. Scienmag.